Masonry Magazine June 1992 Page. 30

Masonry Magazine June 1992 Page. 30

Masonry Magazine June 1992 Page. 30
TABLE 7. MINIMUM RADII FOR CIRCULAR
CONCRETE MASONRY WALLS TO PRODUCE
MINIMUM PROJECTIONS FOR UNITS
WITH NOMINAL 8 INCH LENGTH

Projection Limited to 1/8 in. Projection Limited to 1/4 in.

| Nominal Width (in.) | Required r (ft.-in.) | n Cutting (in.) | Required r (ft.-in.) | n Cutting (in.) |
|---|---|---|---|---|
| 4 | 5′-5″ | 3/16 | 2′-9″ | 5/8 |
| 6 | 5′-5" | 7/16 | 2′-9″ | 1 1/8 |
| 8 | 5′-5″ | 11/16 | 2'-9" | 1 5/8 |
| 10 | 5′-5" | 15/16 | 2.9" | 2 1/8 |
| 12 | 5'-5" | 1 3/16 | 2'-9 | 2 9/16 |

Interior Mortar Joints Maintained at Approximately 1/8 inch

TABLE 8. MINIMUM RADII FOR CIRCULAR
CONCRETE MASONRY WALLS TO PRODUCE
MINIMUM PROJECTIONS FOR UNITS
WITH NOMINAL 16 INCH LENGTH

Projection Limited to 1/8 in. Projection Limited to 1/4 in.

| Nominal Width (in.) | Required r (ft.-in.) | n Cutting (in.) | Required r (ft.-in.) | n Cutting (in.) |
|---|---|---|---|---|
| 4 | 21-5" | None | 10′-10" | 3/16 |
| 6 | 21′-5″ | 1/8 | 10′-10 | 7/16 |
| 8 | 21′-5″ | 1/4 | 10′-10" | 11/16 |
| 10 | 21'-5" | 3/8 | 10′-10 | 15/16 |
| 12 | 21'-5" | 1/2 | 10′-10" | 1 3/16 |

Interior Mortar Joints Maintained at Approximately 1/8 inch

Construction and unit manufacturing tolerances are such that the Radii provided in the Tables may vary by plus or minus one inch.

Specialty Units

Where the size of a radial wall is such that sufficient units are required to make it economically feasible to produce specially designed units, radial units specifically designed to form a curved wall may be desirable. It will be necessary to check with local block suppliers to determine if this is a practical alternative.

Split ribbed units were selected to provide a distinctive appearance to this radial wall

NATIONAL CONCRETE MASONRY ASSOCIATION
P.O. Box 781, Herndon, Virginia 22070