In 2001, the Standard Practice for Bracing Masonry Walls was updated. In the update, all of the tables were adjusted to modular values, and design tables, which change the heights of unbraced masonry above bracing as the wind speed changes, were added to the Appendix.

In 2003, the MCAA published the Masonry Wallbracing Handbook. This handbook contains over 700 different configurations of masonry walls, including openings. While it is based off of the Standard Practice, it is a step-by-step pictorial of where wall bracing should be placed (see Figure B). The MCAA is currently working to develop wall bracing software, which is scheduled for completion by early 2005.

Conclusion
THE COUNCIL FOR Masonry Wall bracing recognizes that it is impossible to prevent the collapse of a masonry wall during construction and that life safety is the primary concern. The Standard Practice and the Masonry Wallbracing Handbook have developed a procedure whereby the wall and area around the wall is evacuated at a prescribed wind speed. While the insurance companies may not agree with this approach, it reaches the goal of preserving the safety of all workers around a masonry job site. This means that, if a wall falls inside of the limited access zone after it was evacuated, the wall bracing was adequate... Adequate enough to make sure that no workers were injured or close to being injured.

Rashod R. Johnson is the Director of Engineering for the Mason Contractors Association of America. He is the incoming Chair of the Council for Masonry Wall Bracing and co-editor of the Masonry Wall Bracing Design Handbook. For more information, he can be reached at rjohnson@masoncontractors.org.

PRECISION SAWING & POLISHING MACHINERY
Model 444 Grinding & Polishing Machine
• 30 HP motor
• 24" wide variable speed belt.
Grinds, hones and polishes block faces and ends (up to 16")
Shown with two floating honing & buffing heads and three rigid diamond heads
Other sizes available

P.O. Box 3754
Knoxville, TN 37927
800-489-0601
Fax: 865-525-2320
Model 511-B Stationary Diamond Saw with
Belt Conveyor
30 HP motor
Heavy duty variable speed hydraulic
tilting arbor (0-90°)
Head turned 90° to saw rail
36" blade guard
20" power raise and lower
28" wide variable speed conveyor

SAWING SYSTEMS
INCORPORATED
www.sawingsystems.com
email: sales@sawingsystems.com
The Voice of the Mason Contractor
CIRCLE 316 ON READER SERVICE CARD
September 2004
Masonry
33


Masonry Magazine December 2012 Page. 45
December 2012

WORLD OF CONCRETE

REGISTER NOW; RECEIVE A FREE HAT!
The first 25 people to register this month using source code MCAA will receive a free MCAA Max Hat (valued at $15.00)! The MCAA Max Hat features a 3D MCAA logo embroidered on front with a

Masonry Magazine December 2012 Page. 46
December 2012

Index to Advertisers

AIRPLACO EQUIPMENT
888.349.2950
www.airplace.com
RS #296

KRANDO METAL PRODUCTS, INC.
610.543.4311
www.krando.com
RS #191

REECHCRAFT
888.600.6060
www.reechcraft.com
RS #3

Masonry Magazine December 2012 Page. 47
December 2012

AMERIMIX
MORTARS GROUTS STUCCOS

Why Amerimix Preblended Products?

576

The choice is CLEAR:

Consistency

Labor reduction

Enhanced productivity

ASTM - pretested to ASTM specifications

Masonry Magazine December 2012 Page. 48
December 2012

MASON MIX
Type S Mortar
QUIKRETE
www.quikrete.com
800-282-5828

MASON MIX
Type 5 Mortar
COMMERCIAL GRADE
QUIKRETE

Our mortar mix on Vail's Solaris was so consistent, every bag was like the next. And the next