Taking only a few minutes to visually inspect a generator before each use can add hundreds of operating hours to the life of the unit.



With an hour meter, it may be useful to keep a notebook close by to keep track of how often the generator is used and for how long. Also, keep an eye on oil consistency and clarity. You may not know how long it has been, but if the oil is black and opaque, it's probably time for a change.

As with refueling, it is important to avoid overfilling. When an engine contains too much oil, it will start burning oil and producing black exhaust, which has potentially damaging effects on the engine. Although most generator engines come equipped with a low-oil shutdown feature that protects it from damage associated with low oil, keeping the oil level topped off will provide further protection.

Visual Inspection

Along with checking oil, it is a good idea to give a quick visual inspection of the unit before each use. Open up the air cleaner assembly and look at the air filter. If it looks dirty or plugged, replace it with a new one. Start the engine and look for anything that is loose or vibrating. If any adjustments need to be made, shut the engine down before tightening.

Look at the generator itself. It should be clean and dry. If it looks dirty, wipe it down with a clean cloth or a soft bristle brush to remove dust particles and other debris. Do not wash with a garden hose or pressure washer. These can introduce water into the cooling air slots and possibly damage the rotor, stator and internal windings of the generator head.

Taking only a few minutes to visually inspect a generator before each use can add hundreds of operating hours to the life of the unit.

Location, Location, Location

Maintaining fuel and oil systems is useless if the generator is not placed in a safe operating location. The position of a generator can mean the difference between a reliable piece of equipment and a maintenance headache. Always operate generators on a level surface. Operating on an angle can cause the lubrication system to fail, locking up all the critical moving parts of the engine. In addition, an angular placement can throw off the fuel level in the carburetor, disrupting the spark plugs, pistons and crankcase.



CUSTOM FABRICATED JACK ARCHES
BUILD WOHE MATERIAIS FROM YOUR JOB SIGHT
CALL: 1.800.660.2542
WWW.ARCHWAYSYSTEMINC.COM
CIRCLE 166 ON READER SERVICE CARD



Nationwide
Parts



BRACING SYSTEMS INC

CONTRACTORS EQUIPMEN
Authorized Lull
Parts
Distributor



Wide Selection
of Hard-to-Find
Parts at
Competitive
Prices!



UPS & Fed Ex
for Quick Delivery!



BRACING SYSTEMS, INC.
888-259-4740
Ask for Jim Parts Dept.
or Fax Orders
630.665.4034
CIRCLE 157 ON READER SERVICE CARD
November 2004
Masonry 31
The Voice of the Mason Contractor


Masonry Magazine December 2012 Page. 45
December 2012

WORLD OF CONCRETE

REGISTER NOW; RECEIVE A FREE HAT!
The first 25 people to register this month using source code MCAA will receive a free MCAA Max Hat (valued at $15.00)! The MCAA Max Hat features a 3D MCAA logo embroidered on front with a

Masonry Magazine December 2012 Page. 46
December 2012

Index to Advertisers

AIRPLACO EQUIPMENT
888.349.2950
www.airplace.com
RS #296

KRANDO METAL PRODUCTS, INC.
610.543.4311
www.krando.com
RS #191

REECHCRAFT
888.600.6060
www.reechcraft.com
RS #3

Masonry Magazine December 2012 Page. 47
December 2012

AMERIMIX
MORTARS GROUTS STUCCOS

Why Amerimix Preblended Products?

576

The choice is CLEAR:

Consistency

Labor reduction

Enhanced productivity

ASTM - pretested to ASTM specifications

Masonry Magazine December 2012 Page. 48
December 2012

MASON MIX
Type S Mortar
QUIKRETE
www.quikrete.com
800-282-5828

MASON MIX
Type 5 Mortar
COMMERCIAL GRADE
QUIKRETE

Our mortar mix on Vail's Solaris was so consistent, every bag was like the next. And the next