Kent State College Of Architecture & Environmental Design

Words: Luke Guinn

Words: Luke Guinn, Marketing Manager for General Shale
Photos: General Shale

Editor’s Note: Masonry was used to help recreate an innovative learning space for students at Floyd E. Kellam High School. Since masonry can help to create safe and innovative schools, we wanted to share this story with MASONRY as it originally ran in MASONRY DESIGN. 

A system approach to the building enclosure is helping prepare the next generation of AEC professionals

The College of Architecture and Environmental Design at Kent State University is preparing the next generation of AEC professionals studying architecture, construction management, interior design, landscaping and urban design. The 107,000 square-foot building houses design studios, building technology laboratories, a lecture hall, library, classrooms, café and is topped off with a green roof.

While the stunning exterior is drawing attention in the design community, the building’s enclosure solutions are quietly addressing three key challenges: moisture mitigation, thermal performance and sustainability. To address each challenge, the enclosure team employed a system performance approach.

As the name implies, a system approach evaluates how each element of the enclosure performs in conjunction with other elements. For example, insulation must be considered in terms of thermal and moisture performance, but also in context with how it functions with air/water barriers and limiting fire propagation in the enclosure. The design team selected the pre-engineered Owens Corning® Enclosure Solutions for the masonry steel stud wall assembly. Following is how each element supported key challenges.

Challenge #1: Guarding Against Moisture Infiltration

Regardless of the form it takes, moisture is a pervasive threat. The closed cell, moisture-resistant rigid nature of the Rigid Foam Insulation used as continuous insulation keeps steel stud framing warmer in cold conditions, and it is adequately permeable to regulate vapor migration, both of which reduces the likelihood of vapor condensation in the stud cavity. It also resists liquid moisture in masonry wall cavities thus guarding against damage caused by moisture accumulation.

Challenge #2: Delivering Thermal Performance

Kent Ohio’s Midwestern location is subject to humid summers and bone-chilling winters. Again, insulation plays an important role in minimizing the effects of thermal bridging. The insulation used delivers long-term stable insulating performance at R-5 per inch.

Challenge #3: Delivering a Sustainable Solution

Given that Kent State College of Architecture is educating future environmental design professionals, the materials selected for the enclosure had to support sustainability. With a minimum of 20 percent recycled content, FOAMULAR® 250 insulation helped the building attain a LEED® Platinum rating, the highest available under the U.S. Green Building Council’s LEED® program. 

It’s All about the System: The exterior wall system included other products documented as a wall “system” to be code compliant and compatible.  These additional components include Pos-I-Tie® masonry veneer anchors from Heckmann Building Products Inc., MortarNet® mortar dropping protection from Mortar Net Solutions™, and Grip-Deck™ continuous insulation anchors with Thermal-Grip® ci prong washers from Rodenhouse, Inc. and one of the dozens of water/air barriers that are pre-approved NFPA 285 compliant with Owens Corning® Enclosure Solutions.

While the system approach was designed to support building performance, it also underscores another important lesson AEC professionals learn – time is money. The streamlined approach to selecting compatible and rated products provided an added layer of efficiency and value for the AEC team working on the project.

With Owens Corning Enclosure Solutions, the design team gained time-saving access to specification guides, CAD and BIM drawing files and other necessary documentation required to demonstrate compliance.

As students at the Kent State College of Architecture and Environmental Design prepare for careers in the AEC industry, their learning environment addresses challenges they will face in their careers.

What gives with head protection? Why workers want to keep their hard hats and ditch safety helmets.
April 2025

Last August, I took my pickup to the dealership for a nagging check engine light. While it was being looked over, I chatted with the salesman I normally deal with, and he told me about the latest and greatest 2025 models. He told me how the twin turbo inl

Government Affairs: Bringing North Carolina to Washington, D.C. and Hopefully Young People to Your Jobsites
April 2025

For you long time members of the Mason Contractors Association of America you likely remember our Annual Washington, D.C. Fly-In where MCAA members from around the country would come to Washington, D.C. meeting with Members of Congress from their home sta

Chairman's Message: While We Are Still Here
April 2025

I truly value my days working on construction sites during the summers of my high school and college days. Some moments in our youth are so clearly meaningful that we file them away in our subconscious to be recalled when life events require inspiration.

Contractor Tip of the Month: The Tough Calls That Define a Leader
April 2025

In construction, every project balances a delicate trio: coordination, precision, and timing. However, beyond blueprints and schedules, leadership demands something far greater—the ability to lead and make difficult decisions that shape the future of a co