Masonry Magazine April 2004 Page. 10

Masonry Magazine April 2004 Page. 10

Masonry Magazine April 2004 Page. 10
Government Affairs

Hexavalent Chromium
Exposure – Next On
OSHA's Hit List

Marian J. Marshall
MCAA, Director of Government Affairs

If you are a movie buff of any sort, you may remember that phrase coined after the release of the second "Jaws" movie-"just when you thought it was safe to go back in the water." Obviously the first film made people a little terrified about swimming in the ocean for fear of a shark attack; the second movie gave folks even greater pause for heading into the deep blue sea. After having reviewed OSHA's draft proposed standard on silica exposure in great detail, only to turn around and have yet another draft standard on hexavalent chromium exposure thrown in the mix, it feels a bit like the jaws of OSHA are about to sink a little deeper into the construction industry.

In February 2002, the Department of Labor was sued by Public Citizen and PACE International Union for failure to issue a new permissible exposure limit (PEL) for hexavalent chromium, or CrVI. The plaintiffs prevailed and now OSHA is under court order to issue-on an expedited basis - a new PEL for CrVI by the end of this year, and the rule must be finalized by January 2006.

For those of you unfamiliar with this chemical, hexavalent chromium is a compound widely used in chrome plating, stainless steel welding, ferrochromium alloy production and wood preserving. CrVI is also found in dyes for textiles and brick, Portland cement, and colored glass and block, among other things. Workers subjected to CrVI are at a greater risk of lung cancer and damage to their respiratory tract, eyes and kidneys.

Hexavalent chromium has also been associated with several skin disorders, ranging from irritation to ulcers. In the case of Portland cement, brick masons sometimes contract allergic dermatitis from wet cement, causing their skin to burn and crack. Some in the industry would argue that the contact dermatitis from Portland cement is caused by the high Ph levels in the cement, not hexavalent chromium itself. For that reason, this draft-proposed standard addresses only exposure from inhalation and eye contact with CrVI, not skin contact; therefore, the standard should most significantly impact those in our industry who do welding. I think it's still important for our readers to be aware of the standard because it contains many of the same provisions as the draft proposal on silica exposure.

The existing PEL for CrVI is 100 micrograms per cubic meter; OSHA is currently considering five PELs: 10, 5, 1, 0.5 and 25 over an eight-hour time weighted average (TWA). OSHA is also considering setting an "action level," typically set as half the PEL, at which point employers would be required to adhere to certain provisions, such as medical surveillance and periodic monitoring. once the PEL had been exceeded.

As drafted, employers would be required to determine the eight-hour TWA exposure for each employee on the basis of a sufficient number of personal breathing zone air samples to accurately characterize exposure on each shift, for each job classification and in each work area.

For tasks where CrVI are present or produced, employers must treat the employees performing these tasks as if they were exposed above the PEL, unless initial exposure assessment indicates otherwise.

If an employer does representative sampling instead of sampling all employees, the employee expected to have the highest exposure must be sampled.

For tasks where CrVI are present or produced, such as abrasive blasting, welding, cutting or torch burning of stainless steel or other materials coated with CrVI, or spray application of paints or coatings containing CrVI, employers must treat the employees performing these tasks as if they were exposed above the PEL, unless initial exposure assessment indicates otherwise.

Periodic monitoring is also required to ensure that the PEL is being met. If initial monitoring reveals employee exposures at or above the PEL, employers must perform monitoring every three months. But better yet, additional monitoring must be performed WHENEVER there has been ANY change in the construction process, raw materials, equipment, personnel, work practices or control methods that may result in new or additional exposures to


Masonry Magazine December 2012 Page. 1
December 2012

December 2012

MASON RY
The Voice of the Masonry Hyduser
Volume 51, Number 12

Fireplaces

Old

INSIDE
Modular Stages
Waterproofing
Refractory Mortar

Visit us online at:
www.masoncontracto

Masonry Magazine December 2012 Page. 2
December 2012

Standing
The Test of Time
Units M100-4, M100-5, M100-6
Purchase date: January 1988
Status: Still fully functional

"After more than 23 years of operation, all my Hydro Mobile units still deliver full return and I still get the sa

Masonry Magazine December 2012 Page. 3
December 2012

Performance and Economy

THROUGH THICK AND THIN™

Everyone wants more from less. ENERSHIELD® gives you exactly that. Premium polymer-based formulations allow optimized application thickness on sheathing and masonry, for fast, easy instal

Masonry Magazine December 2012 Page. 4
December 2012

JOIN THE MCAA AT WOC 2013
GET $1,500 IN SUPPLIES

BECOME A MEMBER AND RECEIVE OVER $1,500 IN MATERIALS AND SUPPLIES*
JOIN THE MCAA DURING THE 2013 WORLD OF CONCRETE/WORLD OF MASONRY IN LAS VEGAS

When you become a member of the M