The Many Lives of Copper Flashings

Words: Dan KamysMarch 2008 CASE STUDY #3

New products constantly flood the construction industry. Some promise and deliver real positive advantages, while others leave questions as to their real advantages over possible new disadvantages. Moisture management has been a real concern in all phases of construction for centuries. It is generally agreed that moisture must be dealt with in a way that will protect a structure for life. Properly designed through-wall flashings are the widely accepted answer to moisture migration in typical cavity wall construction. Proper attention should be given to the location of these flashings, along with the type of materials used.

For hundreds of years, copper has been used in those critical areas where moisture management is a concern. It could be said that copper flashings have stood the test of time and continue to be the most reliable flashing product to assure lasting protection. When choosing a flashing material, longevity should be your main objective. [caption id="attachment_10643" align="alignnone" width="416"]This 50-year-old building remains in remarkably good condition, mostly because of the things that didn't change, including the flashing. This 50-year-old building remains in remarkably good condition, mostly because of the things that didn't change, including the flashing.[/caption]

Case and Point

About 50 years ago, a small U.S. Post Office was built in Hampton, N.H. The structure was a basic brick exterior with a block interior wall. This structure served as a post office for about 22 years and then was sold to a local bank. Due to the location of the building and local zoning regulations, the size and general appearance of the building could not be altered. Thus, the new owners could make only minor changes to the exterior of the structure. Windows and doors were replaced in favor of new, more energy-efficient models, but the approximate size and location remained unchanged.

Twenty-eight years later, the bank relocated, and the building was sold to a national donut chain. Once again, minor changes were undertaken to change the doors and windows, but the location remained the same, as did the structure — and the flashing. The flashing over the windows and door is the original copper fabric flashing that was installed about 50 years prior (see image). The longevity of copper has proven itself through the many lives of this small structure in New Hampshire, and will continue to protect against moisture problems through the years and changes ahead.

Conclusion

This story is not unique. Walk down the streets of a large city, such as Boston or New York, and you'll see extensive use of copper in most of the oldest structures in the city. Will peel-and-stick and PVC flashings be around 50 years from now? New products constantly flood the construction market. Choose wisely. Case Studies: Flashing      
The Importance of Staying Engaged
September 2026

There’s an old adage in Washington, D.C.: “It’s not what you know, it’s who you know.” After moving to Washington, D.C., in January of 2001 for what I thought would be a fun two years working for a Member of Congress while I figured out what I really want

Mentmore Towers, Fort Point, and More
September 2026

The Old Royal Naval College in Greenwich, UK, stands as a sweeping estate that represents the absolute peak of English masonry. Conceived with breathtaking scale and precision, the monumental complex is defined by

The Alhambra
September 2026

High above Granada, Spain, the Alhambra offers masonry professionals something more than an architectural landmark. It is a working lesson in how relatively simple building materials, placed by skilled craftsmen and maintained over generations, can create

The Wall
September 2026

There is a story around Huntley Brothers that some of our guys simply call “The Wall.” I’ve told it enough times over the years that when I start telling it to one of our younger guys, I can see a few of the older ones rolling their eyes. They’ve heard i