Cintec Protects People, Property Against Earthquakes

Words: Dan Kamys

Cintec Protects People, Property Against Earthquakes


Cintec North America, a structural masonry retrofit strengthening, repair, and preservation company, offers solutions to protect people and property against earthquakes. Seistec, a CINTEC Reinforcing Anchor System, is used for seismic repair or for retrofitting seismic upgrading of structures made of brick, stone, terracotta, adobe, or even timber. Seistec internally strengthens the integrity of wall-to-wall, wall-to-roof, and wall-to-floor constructions while remaining sensitive to the original architecture.

CINTEC earthquake experts are currently working with an international delegation to evaluate the structural damage inflicted upon the Christchurch Cathedral in Christchurch, New Zealand during the February 2011 earthquake. The two CINTEC engineers involved with the project are Bill Jordan, who heads CINTEC’s Australian operation, and Sarah Paganoni, who is part of the NIKER project, a group working to protect cultural heritage from earthquake-induced risk.

CINTEC’s Seistec (SEISmic TEChnology) process begins with an inspection of the structure following a site visit by the Engineer of Record. The structure is then computer-modeled and animated using the discrete element technique to visualize potential stresses incurred during seismic loading. This unique software analysis assesses the behavioral probability and the risk inherent to the structure in order to determine the best positioning of the CINTEC Reinforcing Anchor System.

At the site, the CINTEC Reinforcing Anchor System, fashioned out of a steel bar enclosed in a mesh fabric sleeve, is inserted into the structure in need of reinforcement. A specially-developed, non-polymer, cement-like grout is then injected into the sleeve under low pressure.  The grout then fuses with the mesh, expands, and shapes itself around the steel to fit the space. CINTEC uses state-of-the-art dry- or low-volume wet diamond drilling techniques to reduce or even eliminate water damage associated with conventional wet drilling.

The Seistec system may be used in a wide range of masonry materials. The anchor body size and even material type can be adjusted, as can the size of the diameter of the cored hole, based on the condition of parent material and requirements of the Engineer of Record.

HangTite Blended Cement Products Joins the 2026 Masonry Alliance Program as a Gold Partner
November 2025

The Mason Contractors Association of America (MCAA) is excited to announce that HangTite Blended Cement Products has joined the 2026 Masonry Alliance Program (MAP) at the Gold Level.

ONE Spokane Stadium: A Unifying Force in Spokane’s Downtown Core
November 2025

Located in the vibrant arts and entertainment district of Spokane, Washington, ONE Spokane Stadium is a beacon of community, sport, and culture, showcasing the best of multifunctional urban design. Spearheaded by ALSC Architects, the stadium was designed

MCAA And Alan Pettingale Announce Strategic Partnership To Restore America’s Masonry
November 2025

The Mason Contractors Association of America (MCAA) has established a strategic partnership with Alan Pettingale, President and Founder of Specialized Masonry Restoration and creator of the Brick Talk Live podcast and Masonry Restoration Magazine. The par

Westlake Royal Stone Solutions Renews Cornerstone Partnership in the 2026 Masonry Alliance Program
November 2025

The Mason Contractors Association of America (MCAA) is excited to announce that Westlake Royal Stone Solutions will renew its distinguished Cornerstone partnership in the 2026 Masonry Alliance Program.