Safer Rescue Systems With ASSE Fall Protection Standard

Words: Dan KamysSafer Rescue Systems With ASSE Fall Protection Standard

 

 

The American National Standards Institute (ANSI) has approved two American Society of Safety Engineers’ (ASSE) standards addressing fall protection ??? the new ANSI/ASSE Z359.14-2012, Safety Requirements for Self-Retracting Devices for Personal Fall Arrest and Rescue Systems, and the revised ANSI/ASSE Z359.4-2012, Safety Requirements for Assisted-Rescue and Self-Rescue Systems, Subsystems and Components. The standards are part of the Z359 Fall Protection Code.

The new Z359.14 standard establishes requirements for the performance, design, qualification testing, markings and instructions, inspections, maintenance and storage, and removal from service of self-retracting devices, including self-retracting lanyards, self-retracting lanyards with integral rescue capability, and self-retracting lanyards with leading-edge capability (SRL-LE’s). It also establishes requirements for self-retracting devices intended for use in personal fall arrest or rescue systems for authorized persons within the capacity range of 130 to 310 pounds (59 to 141 kg).

In a recent interview, ASSE member Tom Wolner, VP of engineering for Capital Safety and chair of the Z359.4 and Z359.14 subcommittees, discussed how the new standard will change rescue procedures.

“The new Z359.14 standard on self-retracting devices addresses several types of these retractable lanyards and additionally classifies them according to performance. Type A devices, for example, are capable of arresting a fall in less than two feet which is very important in situations where fall clearance is limited. And for the first time, this standard addresses self-retracting devices that may be exposed to a sharp edge in a fall situation. Special testing is included to evaluate and qualify these. Other important additions include expanded requirements for user information and guidelines on inspection expectations depending on the severity of use.”

As for the revised Z359.4 standard Wolner notes, “The major focus is to emphasize the need for preplanning each potential rescue scenario with the expectation that employers and equipment users will use the code to develop effective rescue procedures. This preplanning process includes analysis of rescue needs, equipment selection, training and periodic evaluation of training effectiveness. The equipment types and performance requirements included in the code were specifically geared toward preplanned rescue events to support this approach.”

The revised Z359.4 standard establishes requirements for the performance, design, marking, qualification, instruction, training, use, maintenance, and removal from service of connectors, harnesses, lanyards, anchorage connectors, winches/hoists, descent control devices, rope tackle blocks, and self-retracting lanyards with integral rescue capability comprising rescue systems utilized in pre-planned self-rescue and assisted-rescue applications for one to two persons.

The Importance of Instructor Support
April 2026

Whether you are a new or veteran masonry instructor, we all need support throughout our careers. We can never stop learning, and keeping up with ever-changing technology, materials, and installation techniques can be overwhelming alongside the everyday pr

Vibing Masonry #11: Innovative Concrete Masonry Technologies in Healthcare Design
April 2026

In the high-stakes environment of healthcare design, every material choice is a clinical decision. Architects, engineers, and facility administrators are tasked with creating spaces that are not only resilient and code-compliant but also conducive to heal

Why Termination Bars Still Matter: A Practical Look at Long‑Term Flashing Performance
April 2026

In recent discussions across the masonry industry, I have heard termination bars described as “old school.” The implication is that with modern materials, primerless peel-and-stick flashings, advanced sealants, and structural insulated sheathing, mechanic

Building Solutions: The Critical Role of Cavity Space in Masonry Moisture Control
April 2026

Long before “rainscreen” became a popular term in building science, masonry cavity walls were functioning on that very principle. A brick veneer cavity wall is designed with the expectation that water will penetrate the exterior