Safer Rescue Systems With ASSE Fall Protection Standard

Words: Dan KamysSafer Rescue Systems With ASSE Fall Protection Standard

 

 

The American National Standards Institute (ANSI) has approved two American Society of Safety Engineers’ (ASSE) standards addressing fall protection ??? the new ANSI/ASSE Z359.14-2012, Safety Requirements for Self-Retracting Devices for Personal Fall Arrest and Rescue Systems, and the revised ANSI/ASSE Z359.4-2012, Safety Requirements for Assisted-Rescue and Self-Rescue Systems, Subsystems and Components. The standards are part of the Z359 Fall Protection Code.

The new Z359.14 standard establishes requirements for the performance, design, qualification testing, markings and instructions, inspections, maintenance and storage, and removal from service of self-retracting devices, including self-retracting lanyards, self-retracting lanyards with integral rescue capability, and self-retracting lanyards with leading-edge capability (SRL-LE’s). It also establishes requirements for self-retracting devices intended for use in personal fall arrest or rescue systems for authorized persons within the capacity range of 130 to 310 pounds (59 to 141 kg).

In a recent interview, ASSE member Tom Wolner, VP of engineering for Capital Safety and chair of the Z359.4 and Z359.14 subcommittees, discussed how the new standard will change rescue procedures.

“The new Z359.14 standard on self-retracting devices addresses several types of these retractable lanyards and additionally classifies them according to performance. Type A devices, for example, are capable of arresting a fall in less than two feet which is very important in situations where fall clearance is limited. And for the first time, this standard addresses self-retracting devices that may be exposed to a sharp edge in a fall situation. Special testing is included to evaluate and qualify these. Other important additions include expanded requirements for user information and guidelines on inspection expectations depending on the severity of use.”

As for the revised Z359.4 standard Wolner notes, “The major focus is to emphasize the need for preplanning each potential rescue scenario with the expectation that employers and equipment users will use the code to develop effective rescue procedures. This preplanning process includes analysis of rescue needs, equipment selection, training and periodic evaluation of training effectiveness. The equipment types and performance requirements included in the code were specifically geared toward preplanned rescue events to support this approach.”

The revised Z359.4 standard establishes requirements for the performance, design, marking, qualification, instruction, training, use, maintenance, and removal from service of connectors, harnesses, lanyards, anchorage connectors, winches/hoists, descent control devices, rope tackle blocks, and self-retracting lanyards with integral rescue capability comprising rescue systems utilized in pre-planned self-rescue and assisted-rescue applications for one to two persons.

Moisture in Masonry: A Key Concern
August 2026

As building envelopes become tighter and more performance-driven, clarity around moisture management in masonry applications is more important than ever. In masonry wall assemblies, where water penetration is expected and managed rather than eliminated, t

Revailo Upgrades to Platinum in the 2026 and 2027 MAP
August 2026

The Mason Contractors Association of America (MCAA) is thrilled to announce that Revailo will upgrade their Silver partnership to a prominent Platinum partnership for the remainder of the 2026 MAP and for the duration of the 2027 MAP.

Restoring Structural Integrity: Reinforcement in Masonry Buildings
August 2026

Masonry, as most of us in the trade know and appreciate, remains one of the most durable and time-tested structural systems in the built environment. Structures built throughout Europe and other parts of the world demonstrate that a masonry building is mo

Designing High-Performance Masonry Envelopes: Selecting the Right Air Barrier System
August 2026