Concrete Reinforcing Steel Institute: Use Inch-Pound Markings

Words: Dan KamysConcrete Reinforcing Steel Institute: Use Inch-Pound Markings

 

 

The Concrete Reinforcing Steel Institute (CRSI) Board of Directors is urging all CRSI producer members to revert to an inch-pound bar marking system for all sizes and grades of deformed reinforcing steel products. CRSI members produce more than 90 percent of domestic reinforcing steel.

The intention of this resolution is for all new rollings of reinforcing steel products to be marked with inch-pound bar markings no later than Jan. 1, 2014. Providing a 25-month phase in period should permit producer members sufficient time to re-tool finish roll inventory to the inch-pound marking system as rolls need to be replaced, significantly reducing or eliminating the need to unnecessarily cut new rolls to meet the resolution.

As the ASTM specifications for reinforcing steel products permit reinforcing bars to be marked in either soft metric, or inch-pound markings, existing inventory of soft metric bars can continue to be sold alongside inch-pound marked bars during and after the Jan. 1, 2014, phase-in target.

The intention of this resolution is to reduce confusion and the chance of errors or delays from the construction supply chain. CRSI members are strongly encouraged to revert to the inch-pound marking system for steel reinforcing bars as soon as practical to minimize any additional confusion to the supply chain of steel reinforcing bars.

This change is the result of several actions. The Federal Highway Administration no longer mandates metrification of federally funded road and bridge construction projects and all state Departments of Transportation no longer require materials to be specified and sourced in metric sizes/quantities. Additionally, a large majority of the non-governmental construction community never adopted metric measurements in their plans and specifications. The American Concrete Institute (ACI), through their Technical Activities Committee, has strongly encouraged CRSI members to mark reinforcing bars with traditional inch-pound size designations. ACI is the standards body within the United States responsible for developing the concrete building code. The concrete building code and other ACI documents reference the inch-pound size as the primary designation.

Why Mast Climbers Have Become Indispensable in Modern Masonry
August 2026

Masonry is one of the oldest trades in the construction industry, yet it continues to evolve. While the principles of laying brick and stone have remained largely unchanged for centuries, the equipment supporting masons has undergone a dramatic transforma

Moisture in Masonry: A Key Concern
August 2026

As building envelopes become tighter and more performance-driven, clarity around moisture management in masonry applications is more important than ever. In masonry wall assemblies, where water penetration is expected and managed rather than eliminated, t

Revailo Upgrades to Platinum in the 2026 and 2027 MAP
August 2026

The Mason Contractors Association of America (MCAA) is thrilled to announce that Revailo will upgrade their Silver partnership to a prominent Platinum partnership for the remainder of the 2026 MAP and for the duration of the 2027 MAP.

Designing High-Performance Masonry Envelopes: Selecting the Right Air Barrier System
August 2026